READQ TD command
Reads transient data (TD) from a queue (after which the record is no longer available). In Smalltalk, the parameters of the READQ TD command are contained in two classes: CICSReadqtd and CICSReadqtdResult.
See CICS Application Programming Reference for the syntax of the command and a description of its parameters.
Defined instance methods
Parameters supplied to CICS in CICSReadqtd
 
Parameter
Instance method
Mode
Type
Notes/exceptions
NOSUSPEND
nosuspend
Input
Switch
 
QUEUE(name)
queue:
Input
Fixed(4)
 
SYSID(systemname)
sysid:
Input
Fixed(4)
Remote systems only
Parameters returned by CICS in CICSReadqtdResult
 
Parameter
Instance method
Mode
Type
Notes/exceptions
LENGTH(data-area)
length
Output
Binary 16
 
RESP
resp
Output
Fixed(2)
Inherited from CICSResult.
RESP2
resp2
Output
Fixed(2)
Inherited from CICSResult.
SET(ptr-ref)
set
Output
Variable
 
Example
Reads data from a transient data queue and assigns SET result.
| result setValue |
result := CICS readqtd
queue: 'TDQU';
exec.
setValue := result set.
Last modified date: 07/09/2019